Nonmetal Ultrasonic detector

 Nonmetal Ultrasonic detector

Model No.︰SYC62

Brand Name︰-

Country of Origin︰China

Unit Price︰-

Minimum Order︰1 pc

Inquire Now

Product Description

Specification

Technology code for testing of building foundation piles JGJ106-2003

Technical specification of dynamic pile tests for highway engineering JTG/TF81-01-2004

Technology specification for inspection of concrete defects by ultrasonic method CECS 21:2000

Technical specification for detecting strength of concrete by ultrasonic-rebound combine method CECS 02:2005

Technical specification for geotechnical investigation method GB 50021-2001

Purpose

Testing building foundation piles by crosshole ultrasonic wave method .

Inspecting concrete defects by ultrasonic method, such as uncompacted place, cellular hole area

Detecting concrete strength by ultrasonic-rebound combined method

Detecting concrete crack depth by ultrasonic method

Detecting the wall defects of the hole by one transmitter and two receivers

Detecting the strength performance of geotechnical investigation, rock, concrete, etc

Performance

Fast, precise and automatic to judge the sound parameters. Real-time wave display to assure test efficiency

Graphically display the test data, the user can view result directly.

Can connect with the test hammer directly to detect the concrete strength. The function has been applied for national patent.

Can receive signal with strong sensitivity more than 10m without defects in concrete.

The host can supply energy to transducer without external power.

Standard USB storage with big capacity

Interior lithium battery can supply working power more than 6 hours. And more than 12hours combined with external lithium battery.

Portable, small and light apparatus(1.75kg)

Extending function to test concrete thickness by impact-echo method

Professional and powerful analysis software on Windows system can output the data to Excel or word for advanced analysis.

 

Technical data

Item

Specification

Main control unit

High-performance embedded computer

Input method

keyboard

Interface

USB

Receive channel

Two

Transmission mode

Continuous and external

Receive sensitivity

30uv

Amplifier bandwidth

10kHz to 300kHz

Sound time accuracy

0.05us

Display

640*480 high brightness TFT panel

Storage

1G(Interior)

2G(U-Disk)

Max sample data length

64k

Trigger voltage

65,125,250,500,1000(selectable)

Amplifier gain

82dB

Sample periods

0.05us to 6.4us,8grade adjustable

Amplifier resolution

0.39%

Power

Interior lithium battery works more than 6hours

External lithium battery works more than 6hours (Optional)

DC 12V interface

AC 100V-240V,50/60HZ

Size

260*185*60mm

Weight

1.75kg(including the battery

Temperature

-10~ +40

Payment Terms︰ TT